Complex reconstructive surgery following removal of extra-intracranial meningiomas, including the use of autologous fibrin glue and a pedicled muscle…
2014
Abstract Background Skull reconstructive surgery is critical to prevent cerebrospinal fluid (CSF) fistulas and infections, and to ensure good aesthetic results in meningiomas surgery. Methods A 65-year-old woman was surgically treated for a bilateral parasagittal meningioma with complete superior sagittal sinus (SSS) involvement, and an intra-extracranial extension, determining a significant cranial defect at the vertex. A Simpson I resection was achieved. Postoperatively a considerable and not conservatively repairable CSF leak was detected. Surgical revision of the wound with repair of the fistula and complex reconstructive operation was performed including a combination of techniques and…
Autologous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part I: Intracranial surgical procedure.
2014
Background: Hemorrhages, cerebrospinal fluid (CSF) fistula and infections are the most challenging postoperative complications in Neurosurgery. In this study, we report our preliminary results using a fully autologous fibrin sealant agent, the Vivostat ® system, in achieving hemostasis and CSF leakage repair during cranio‑cerebral procedures. Methods: From January 2012 to March 2014, 77 patients were studied prospectively and data were collected and analyzed. Autologous fibrin sealant, taken from patient’s blood, was prepared with the Vivostat ® system and applied on the resection bed or above the dura mater to achieve hemostasis and dural sealing. The surgical technique, time to bleeding c…
Natura abhorret a vacuo. Future perspectives of autologous fibrin glue. Is it time for reappraisal?
2017
Aulogous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part II: Vertebro-spinal procedures.
2015
Background Epidural hematomas, cerebrospinal fluid fistula, and spinal infections are challenging postoperative complications following vertebro-spinal procedures. We report our preliminary results using autologous fibrin sealant as both fibrin glue and a hemostatic during these operations. Methods Prospectively, between January 2013 and March 2015, 68 patients received an autologous fibrin sealant prepared with the Vivostat(®) system applied epidurally to provide hemostasis and to seal the dura. The surgical technique, time to bleeding control, and associated complications were recorded. Results Spinal procedures were performed in 68 patients utilizing autologous fibrin glue/Vivostat(®) to…